2025 © Allparts Equipment & Accessories. All Rights Reserved.
111814-01 GAS VALVE HONEYWELL NG RV8310E
Reference Item Only
Part Number
111814-01
Previous Gas Valve Information
Overview The RV8310D,E Millivolt Receiver/Modulating Gas Valves were powered by dual thermopile generators, with a 60,000 Btu per hour capacity (1 in. pressure drop for straight-through configuration).
This design is ideal for vented fireplace/space heating applications. Features T
The RT8220A Transmitter is used with this product. Product Specifications Application Vented fireplace and space heaters Includes:
Q313 with 1/4 in. quick-connect or spade terminal Used With RT8220A Transmitter
Comments Fan Connection-- 120 Vac, 50/60 Hz, 2A maximum; 1/4 in. spade terminals.
Approvals, Canadian Standards Association CSA Certificated 158158-250000102 Voltage
(2) Q313 thermopile generators with a minimum of 500 mV in open circuit Ambient Temperature Range (F) 0 F to 175 F Ambient Temperature Range (C) -18 C to +79
C Pipe Connection Main Gas-- 3/8 in. NPT Thread;
Pilot Gas-- 7/16-24 UNS Pressure Tapping European Pilot Gas Flow 1700 BTU at 4.0 in. wc pressure drop Pressure Regulator Setpoint (in. wc)
Liquid propane (LP): 10.0/6.3 in. wc
The 111814-01 Honeywell Natural Gas valve works with various models of Vented gas log systems, Vented Decorative Gas Log Heaters built by FMI and branded under Design Dynamics.
HCA-24-RFN
HCM-18-RFN
HCM-24-RFN
HKE-18-RFN
HKE-18-RFP
HKE-24-RFN
Vermont Casting Majestic Natural Gas Models:
DVRT36
DVRT39
DVRT43
DV360
This is also Vermont castings part number 200003719
Overview The RV8310D,E Millivolt Receiver/Modulating Gas Valves were powered by dual thermopile generators, with a 60,000 Btu per hour capacity (1 in. pressure drop for straight-through configuration).
This design is ideal for vented fireplace/space heating applications. Features T
The RT8220A Transmitter is used with this product. Product Specifications Application Vented fireplace and space heaters Includes:
Q313 with 1/4 in. quick-connect or spade terminal Used With RT8220A Transmitter
Comments Fan Connection-- 120 Vac, 50/60 Hz, 2A maximum; 1/4 in. spade terminals.
Approvals, Canadian Standards Association CSA Certificated 158158-250000102 Voltage
(2) Q313 thermopile generators with a minimum of 500 mV in open circuit Ambient Temperature Range (F) 0 F to 175 F Ambient Temperature Range (C) -18 C to +79
C Pipe Connection Main Gas-- 3/8 in. NPT Thread;
Pilot Gas-- 7/16-24 UNS Pressure Tapping European Pilot Gas Flow 1700 BTU at 4.0 in. wc pressure drop Pressure Regulator Setpoint (in. wc)
Liquid propane (LP): 10.0/6.3 in. wc
The 111814-01 Honeywell Natural Gas valve works with various models of Vented gas log systems, Vented Decorative Gas Log Heaters built by FMI and branded under Design Dynamics.
The 111814-01 Honeywell Natural Gas valve works with the following models:
HCA-24-RFN
HCM-18-RFN
HCM-24-RFN
HKE-18-RFN
HKE-18-RFP
HKE-24-RFN
Vermont Casting Majestic Natural Gas Models:
DVRT36
DVRT39
DVRT43
DV360
This is also Vermont castings part number 200003719
Write Your Own Review
No
No