The 0.584.027 Sit Proflame GTMFS Series Transmitter is the remote SIT controls transmitter that is used to control room temperature on many gas log sets including fireplaces made by Travis Industries, Regency Fireplaces, Comfort Glow, Empire, FMI, Design Dynamics, Vanguard, Napoleon, Monessen,  and several other fireplaces.

The Proflame 0.584.027 Transmitter requires 4.5 DC Volts,3 AAA batteries and has a radio frequency of 315 MHz.

This Sit Controls GTMFS 0.584.027 is designed to control the on/off main burner operation, flame height modulation, fan speed control, split flow control and provides on/off and Smart thermostatic control of the hearth appliance.


We are sorry but REMOTE TRANSMITTERS and REMOTE RECEIVERS are NOT RETURNABLE for refunds!


These items comes with a 90 day warranty for exchange only.
Please look at all pictures carefully and study your manual before you purchase this item because no returns for refunds will be accepted.

We do offer free testing on most Remote Transmitters and Remote Receivers for customer who choose to send these items in for testing.


Service Note:

It is recommended to use standard alkaline batteries in these transmitters. The use of lithium ion batteries has been found to throw an ER9 code due to higher voltage. If you have an ER9 code, transmitter battery measure error, appearing on your unit and you have lithium batteries installed, swap them out for standard alkaline batteries. If the code reappears, the remote will need to be replaced. 

To Program Your New Remote Receiver and Transmitter:

Install 4 New AA Energizer or Equivalent alkaline batteries into the receiver.
Note the polarity of the batteries and make sure to insert them into the battery bay and indicated on the Battery door cover (+/-)
After installing the batteries, you should hear 1 beep telling you the receiver has power and is ready to be programmed.

Note:
If you do not hear 1 Beep remove the batteries and allow the receiver to set for 10 minutes and try the battery installation process again.

Next place the receiver 3 position slider switch into middle location on your receiver, with the large switch cover on this would be the " Remote" position

Push the program button "PRG" one time and you should hear the 3 short beep telling you the receiver is now ready to accept a new code from the remote transmitter.

Note: If you do not hear 3 Beeps remove the batteries and allow the receiver to set for 10 minutes and try the battery installation and programming process again.

Install 3 New AAA Energizer or Equivalent alkaline batteries into the transmitter.
Now with the new batteries installed push the On/Off button of your remote transmitter and you should hear 4 beeps from the receiver telling you the receiver and the remote are now paired with the same RF code and ready to be used.

The System is now initialized.