J4702 Gas Valve Propane LP Gas Vent Free SIT Controls
J4702
Lennox IHP Propane Gas Millivolt is a Split system remote ready milli-volt
control for use in unvented appliances including Vent-Free Logs, Ventfree Gas Fireplaces,
and other Vent Free decorative applications.
The Lennox IHP J4702 Gas Valve was used on many
different models of Vent Free fireplaces from IHP, Lennox, Superior, Asteria
and Firewerks including the following partial list of models:
Astria Gas Fireplace:
- Arcadia18MP
- Arcadia24MP
- Sheridan18PM
- Sheridan24PM
Superior Gas Fireplaces:
- CF5500CMP
- CF5-CMP
- CF6500CMP
- CF6-CMP
- CFPF-CMP
- CFST-CMP
- CGI-BAY
P
- CGI-BAY
PX
- KVF-38
RMP
- PH36P-FS
- PH-36P-IN
- PH36P-ZC
- VF4000-CMP-2
- VF4-CMP
- VF5000-CMP-2
- VF5-CMP
- VF6000-CMP-2
- VF6-CMP
- VFGL-18VSP-3
- VFGL-18VSP-4
- VFGL-24VSP-3
- VFGL-28VSP-3
- VFPF-CMP
- VFPF-CMP-2
- VFST-27MP
- VFST-CMP
- VFST-CMP-2
- VF18NPTB
Lennox Gas Logs:
- SHGL-18VP-R
- SHGL-24VP-R
- LSVFSD-18
- LSVFSD-24
- LSVFSD-30
- VF-18P-BTB
- VF-18P-PDG
- VF-24P-BTB
Firewerks Gas Log Sets:
- SMA18VPA
- SBJ18VPA
- SMA24VPA
- SBJ24VPA
- VFRMV18PA
- VFRMV24PA
- MVO18VPA
- MVO24VPA
- MPF18VPA
- MPF24VPA
- VTDMV18PA
- VTDMV24PA
- VFRMV18NB
This J4702 a remote ready gas valve and has the HI/LO burner adjustment with manually operated knob with variable flame adjustment.
The J4702 IHP gas Valve will have the Sit Controls Model 0.820.636 and must be replaced with the exact same gas control valve.
Split-system millivolt controlled liquid propane gas valve for use in vented appliances.
HI/LO burner adjustment with manually operated knob
Minimum voltage 145mV Coil resistance 2.25±0.5
Thermo-Electric Unit Hold-in current less than 200Ma
Drop-out current Greater than 80mA with coil resistance 0.018± 0.003
Gas type Propane Gas HI/LO action Manual Pressure set-point 10.0” w.c. ± 0.4
Range of adjustment 10.0” w.c. -6.3” w.c. Set at 30K btu/hr
Thermocouple connection M8x1
Propane "LPG" Gas Inlet 3/8 in. NPT
Propane "LPG" Gas Outlet 3/8 in. NPT
Maximum Propane Gas inlet pressure 1/2 PSIG Ambient operating
Temperature 32° to 175° F
Maximum @ 1 in. w.c. pressure drop 162,000 BTU per hour Regulation capacity 8,100 to 315,700 BTU AP per hour
Maximum Inlet Pressure 1/2 PSIG