The Annovi Reverberi RRV4G40-PKG, 1" hollow shaft triplex pump kit is ready for direct drive coupling to gas or diesel engines using the equipped AR41866 mounting flange.
This pump is manufactured with a brass pump head suitable for a wide range of conditions.
The RRV4G40-PKG can produce up to 4000 Max PSI, 4 Max GPM, and is designed to operate at 3400 RPM.
Constructed with frictionless bronze connecting rods and ceramic pistons, the RRV4G40-PKG boasts a sleek compact design.
RRV4G40-PKG Features:
Pump: RRV4G40HD-F24
Max PSI: 4000Max GPM: 4RPM: 34001” Hollow ShaftF24 - Gas Engine Flange
- Thermal Relief Valve: TPP140
- 3/4” F Nut: AR7366
- 1/2” M Nipple: AR7368
- Inlet Filter: AR7369
- Gymatic Unloader: AR20992
- Quick Connect Coupler: AL-QC3/8B
Plunger Pumps are designed for a wide variety of high pressure washing applications.
They feature a brass head and are constructed with die-cast bodies.
Precision cast cooling fins are anodized for maximum heat dissipation.
Carefully engineered supports coupled with oversized, drive side needle bearings and idle side ball bearings assure positive alignment and centering of the drive shaft in relation to the crankcase.
Solid drive shaft pumps use ball bearings on both sides.
Internal components include purpose built, solid ceramic plungers for long life and durability.
Specially designed Ultraform® valve cages provide positive seating and extended life.
One-piece connecting rods, made from specially alloyed aluminum, are oversized for strength and load disbursement.
These pumps are designed for electric motor or gasoline driven belt drive systems, or electric motor, and gasoline engine direct drive coupling systems.
A.R. Pump Care:
- To prevent freezing use Environmentally Friendly or R.V. Antifreeze. (Always use for winter storage).
- Change oil every 3-5 months or every 500 hours of operation (initial break-in oil change after first fifty hours).
DO NOT change oil in the RP, RQ, RM, SRM, RX, SJ & XJ Series Pumps.
- Flush water valves and detergent injectors with plain water on a regular basis after use.
- Use Line Strainer, 50 mesh minimum.
- Never store pump with water in it.
- Consult local service dealer or AR North America for chemical usage.