780-845 Robertshaw Ignition Control Module

In stock
Part Number
780-845
$179.88
Part Number: 780-845
Compatible Brands: Robertshaw
Shipping Weight: 2 Lbs
780-845 is a Robertshaw ignition control module for gas fireplaces with thermostat control. When the thermostat calls for heat, the 780-845 control simultaneously initiates ignition sparking and opens the pilot valve portion of the gas valve. The pilot flame recognition stops ignition sparking and opens the main valve portion of the gas valve. The pilot burner flame is continuously monitored at a synchronous frequency for the duration of the heating cycle. Should the pilot flame fail during the heating cycle, the control will shut off the main valve until the pilot flame is established.

The 780-845 lockout ignition control provides 90 seconds of spark, followed by a 6 minute time delay (purge) between ignition attempts. After three tries, if no pilot flame is sensed, the control goes into a one-hour lockout period. At the end of the lockout period, if the demand for heat is still present, the unit will repeat the three tries for ignition.

During lockout, you may override the auto-system and manually reset the unit at the thermostat. The green diagnostic LED will be on continuously for normal operation. The LED will be off for internal lockout and will flash continuously for problems external to the control (ie. not sensing flame).
When the thermostat calls for heat, the 780-845 control simultaneously initiates ignition sparking and opens the pilot valve portion of the gas valve. Pilot flame recognition stops ignition sparking and opens the main valve portion of the gas valve. Pilot burner flame is continuously monitored at a synchronous frequency for the duration of the heating cycle. Should the pilot flame fail during the heating cycle, the control will shut off the main valve until the pilot flame is established.

The 780-845 lockout ignition control provides 90 seconds of spark, followed by a 6-minute time delay (purge) between ignition attempts. After three tries, if no pilot flame is sensed, the control goes into a one-hour lockout period.
At the end of the lockout period, if the demand for heat is still present, the unit will repeat the three tries for ignition.

During lockout, you may override the auto-system, and manually reset the unit at the thermostat. The green diagnostic LED will be on continuously for normal operation. The LED will be off for internal lockout and will flash continuously for problems external to the control (ie. not sensing flame).

Specifications:
  • Input Voltage: 24 VAC to 50/60 Hz
  • Transformer: 24 VAC / 20 VA
  • Safety lockout timing: 90 seconds
  • Spark rate: 4 to 15 sparks per second
  • Pilot valve, Main valve: 1 amp at .5 PF
  • Combined load: 1.5 at .4 PF
  • Flame sense current: .7 mA DC @ 25°C / 24 VAC
  • Maximum total current load: 1.5 amp
  • Flame failure reignition time: 2 seconds maximum
  • Ambient temperature rating: 40 to 175° (?40 to 80°C)
  • Relative humidity: 95% noncondensing at 104°F
  • Factory Model # SP845 (SP 845) 100-00834-41
Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
No
No