Rating:
100 % of 100
0.584.027 PROFLAME TRANSMITTER GTMFS SIT CONTROLS
0.584.027 PROFLAME TRANSMITTER GTMFS SIT CONTROLS Replacement proflame 2 transmitter by SIT Flame control on the 0.584.027 transmitter 0.584.027 replacement Proflame remote

0.584.027 TRANSMITTER PROFLAME GTMFS SERIES SIT CONTROLS

In stock
Part Number
0.584.027
$116.91
Part Number: 0.584.027
Brand: Sit Proflame
Shipping Weight: 1 Lbs
Non Returnable
Click here to agree to Allpart's Return Policy.
Please see our return policy
⇧ Check The Box If You Want To Proceed.

The 0.584.027 Sit Proflame GTMFS Series Transmitter is the remote SIT controls transmitter that is used to control room temperature on many gas log sets including fireplaces made by Travis Industries, Regency Fireplaces, Comfort Glow, Empire, FMI, Design Dynamics, Vanguard, Napoleon, Monessen,  and several other fireplaces.

The Proflame 0.584.027 Transmitter requires 4.5 DC Volts,3 AAA batteries and has a radio frequency of 315 MHz.

This Sit Controls GTMFS 0.584.027 is designed to control the on/off main burner operation, flame height modulation, fan speed control, split flow control and provides on/off and Smart thermostatic control of the hearth appliance.


We are sorry but REMOTE TRANSMITTERS and REMOTE RECEIVERS are NOT RETURNABLE for refunds!


These items comes with a 90 day warranty for exchange only.
Please look at all pictures carefully and study your manual before you purchase this item because no returns for refunds will be accepted.

We do offer free testing on most Remote Transmitters and Remote Receivers for customer who choose to send these items in for testing.

Need Help? Call us:

1-269-685-4123

Related Items

To Program Your New Remote Receiver and Transmitter:

Install 4 New AA Energizer or Equivalent alkaline batteries into the receiver.
Note the polarity of the batteries and make sure to insert them into the battery bay and indicated on the Battery door cover (+/-)
After installing the batteries, you should hear 1 beep telling you the receiver has power and is ready to be programmed.

Note:
If you do not hear 1 Beep remove the batteries and allow the receiver to set for 10 minutes and try the battery installation process again.

Next place the receiver 3 position slider switch into middle location on your receiver, with the large switch cover on this would be the " Remote" position

Push the program button "PRG" one time and you should hear the 3 short beep telling you the receiver is now ready to accept a new code from the remote transmitter.

Note: If you do not hear 3 Beeps remove the batteries and allow the receiver to set for 10 minutes and try the battery installation and programming process again.

Install 3 New AAA Energizer or Equivalent alkaline batteries into the transmitter.
Now with the new batteries installed push the On/Off button of your remote transmitter and you should hear 4 beeps from the receiver telling you the receiver and the remote are now paired with the same RF code and ready to be used.

The System is now initialized.

Write Your Own Review
Only registered users can write reviews. Please Sign in or create an account
No
0.584.027, 0584027, 0-584-027, 0 584 027