Reddy Heater Portable Low Pressure Kerosene Heater Model:
R35D, R35E, R40, R40T, R50BT, R55A, R55B, R55BT, R60, R60A, RM60,R70DT, R70ET, R70D, RH100VT, R110C, R110B,R110BT,R115, R115C, R115DT, R115T, RM115, RH125T, RH125AT, RHD125T, RL125T, RE125T, R155B, R155C, R155D, RM155, R165AT, R165CT, R165DT, RH170T, RH170AT, RHD170T, RE170T, RL170, R200A, R200BT, RM200AT, RE200T, RHD200T
Master Heater Portable Low Pressure Kerosene, Diesel and JP8 Heater Model:
B50H, B50J, B55, B55CT, B60, B70D, B70DT, B70ET, B110B, B110BT, B115, B115DT, M125T, M125AT, B150J, B150JT, B155T, B155CT, B155DT, B165A, B165CT, B165DT, M170T, M170AT, M200T, M200AT, B165AT, B200AT, B200BT,
Universial Portable Low Pressure Kerosene, Diesel and JP8 Heater Model:
UK55,UK70T, UK115T, UK165T
ALL-PRO Portable Low Pressure Kerosene, Diesel and JP8 Heater Model:
PK55, PK60, PK70T, PK110, PK115T, PK165T
Remington Portable Low Pressure Kerosene, Diesel and JP8 Heater Model:
REM35B, REM35C, REM40, REM50C, REM55A, REM55B, REM60, REM110B, REM110BT, REM115, REM115T, REM150E, REM155B, REM200AT
TEST PROCEDURE
1Check Ignitor
Disconnect ignitor wires from ignition control assembly. Measure the resistance of the ignitor at the terminals with an ohmmeter (use 0-200 OHM scale). Ignitor resistance should measure 30 to 175 OHMS. If resistance measures outside of this range, then ignitor is defective and should be replaced.
2Check Ignition Control Assembly
Remove fuse cover and check fuse (70,000 to 200,000 Btu models only). If fuse is blown replace it with a GMA- 10 fuse. Disconnect motor red and white wires from control. With Ignitor wires disconnected, attach voltmeter leads to the ignitor terminals (labeled IGNITOR). Use the 0 to 200 V.A.C. scale. Plug power cord into a grounded 120V/60 Hz outlet. Meter should read 120V(rms) for approximately 10 seconds. If voltage reads 0 or stays at 120 for more than 10 seconds, the control is defective and should be replaced.
II. TECHNICAL SERVICE DEPARTMENT
The Technical Service Department, located in Martin, Michigan, is committed to assisting our Authorized Service Centers to increase their service knowledge, so that they can provide prompt, efficient service.
The Service Manual covers the majority of problems that are associated with the heaters.
However, as with any product, certain problems can arise which have not been covered.
If such problems arise, please call the Technical Service Department's number, 1-877-475-5660, to address these technical problem areas. If you need assistance for ordering parts, billing questions, etc. you should contact 1-877-475-5660.